Access Control Networking Equipment dealer in Kenya
Hikvision DS-K7PEB Emergency Break Glass
Hikvision DS-K2M061 Secure Module
Roisock Wireless PIR Motion-Sensor
Lightsys GSM-module for Alarm-system
Prosys 140 Alarm Control-Panel
The Prosys 140 Alarm Control-Panel has the following features;
- Â 8 zones expandable up to 128 4 or 8 system partitions
- Auto-Installâ„¢ technology assures simple installation Bus test for pinpointing faulty wiring
- Triple EOL termination for Grade 3: Allows alarm, tamper and mask on each single zone 4 groups per partition – enabling partial arming of a group of zones within a partition
- Up to 32 schedules for arm/disarm and output control, supporting 2 intervals per day
- Â High security features such as double password, keypad disable during scheduled arm, and 2 separate buses
- 6 fully programmable utility outputs onboard – one 3A relay, one 500mA open collector and four 70mA O.C.
-  False alarm prevention features – such as fire alarm verification, programmable swinger shutdown, cross zoning, pulse counting, transmission delay, audible/visual exit delay
- Â One-man walk test Watchdog periodically performs self-test of the system
- Â Up to 99 user codes
- Â Up to 999 event log
- Â Box tamper
- Â Bell/Siren tamper
- Â Built in Siren Driver (900 mA)
- Â Automatic fuses
Prosys 116 Alarm Control-Panel
The Prosys 116 Alarm Control-Panel has the following features;
- 8 zones expandable up to 128
- 4 or 8 system partitions
- Auto-Install technology assures simple installation
- Bus test for pinpointing faulty wiring
- Triple EOL termination for Grade 3: Allows alarm, tamper and mask on each single zone
- 4 groups per partition – enabling partial arming of a group of zones within a partition
- Up to 32 schedules for arm/disarm and output control, supporting 2 intervals per day
- High security features such as double password, keypad disable during scheduled arm, and 2 separate buses
- 6 fully programmable utility outputs onboard – one 3A relay, one 500mA open collector and four 70mA O.C.
- False alarm prevention features – such as fire alarm verification, programmable swinger shutdown, cross zoning, pulse counting, transmission delay, audible/visual exit delay
- One-man walk test
Secolink 16-Zone Intruder Alarm Control-Panel
The Secolink 16-Zone Intruder Alarm Control-Panel has the following features:
- Â Concept of Modular System
- Â 1-4 Partitions
- Â 3-31 user codes
- Â 8-16 wired zones
- Â 1-15 keypads in system
- Â 512 events memory
- Â Remote system programming PSTN, GPRS, or LAN,
- Â Remote control macro command
- Â Remote arming, disarming, alarm clearing, with user code, by cell phone
- Â Room Temperature request by cell phone and temperature value results by SMS
IDS X64 8-Zone Control panel
The IDS X64 8-Zone Control panel has the following features;
•   8 Zones expandable to 64 zones
•   8 partitions
•   Supports up to 8 keypads
•   5 fully programmable outputs expandable up to 25 outputs
•   Hybrid, zone expanders available for both wired & wireless devices
•   8 Zone plug in expander module, zones 9 to 16 (code 860-06-X-08PI)
•   8 Bus expander modules, max 6 per system (code 860-06-X-08S)
•   16 detector wireless receiver, max 4 per system (for a total of 64 wireless zones) (code 860-07-X64-0462)
•   128 user codes