The UPS – Uninterruptible Power Supplies Protects against power interruptions.
This is by providing a battery backup power in the case where common power problems such as a blackout, voltage sag, or voltage surge present themselves.
When incoming utility power drops below or surges above safe voltage levels, then the Uninterrupted Power Supply switches to a Direct Current (DC) battery power and then inverts it to an Alternating Current (AC) power to power connected equipment’s.
There are three major types of UPS’s, theses are:
1.A Standby UPS
2.Line Interactive
3.Online devices
These three types generally meet both the enterprise and consumer needs, in their own different ways.
In addition each type keeps network devices operational when power is unavailable. With features such as energy metering vary by model.
Mecer 650 va ups
Apc 2200va ups
- Max Configurable Power (Watts): 1.98kWatts / 2.2kVA
- Output Voltage Distortion: Less than 5 %
- Â e
- Transfer Time: 4 ms typical : 8 ms maximum
- Input frequency: 50/60 Hz +/- 3 Hz Auto-sensing
- Input voltage range for main operations: 75 - 154 Adjustable, 82 - 144V
- Typical recharge time: 3hour(s)
Apc 1200va ups
- Output power capacity;Â 650 Watts / 1.2kVA
- Output Connections;Â (6) IEC 60320 C13 (Battery Backup)
- Nominal Output Voltage;Â 230V
- Input Connections;Â IEC 60320 C14
- Cord Length;Â 1.2meters
- Automatic Voltage Regulation (AVR) which automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment.
- Dataline surge protection provides protection of connected equipment from power surges on the data lines.
- USB connection
- Battery-protected and surge-only outlets reserves power capacity and run time for connected equipment that require UPS battery back-up while providing surge only protection for less critical equipment
- LED status display Quickly understand unit and power status with visual indicators. Consequently, Audible alarms provides notification of changing utility power and UPS power conditions
- APC UPS 1200VA features intelligent battery management thus maximizing battery performance, life, and reliability through intelligent, precision charging. Battery failure notification also provides early-warning fault analysis on batteries enabling timely preventive maintenance
Apc 650 va ups
- APC Back-UPS 650VA, 230V, AVR, Universal Sockets
- Max Configurable Power (Watts)
- 325 Watts / 650VA
- Output Frequency (sync to mains) 50/60 Hz +/- 1 Hz Sync to mains
- Topology Line interactive
- Waveform type Stepped approximation to a sinewave
- Transfer Time 4 ms typical : 6 ms maximum
- Input frequency 50/60 Hz +/- 3 Hz Auto-sensing
Mercury 3000 va ups
Mercury 2000va ups
Mercury 1550 va ups
- Capacity:Â 1550VA/930Watts
- 4X UNIVERSAL SOCKET,
- 2X 8.2AH BATTERY
- Current:Â 7.2A max
- UK POWER CORD
- Input:Â Voltage 220-230VAC , Voltage Range: 140-300 VAC , Frequency: 50 / 60Hz, Current:7.2A Max
- Output:Â Voltage Regulation (Bat.Mode): +/-10%, Frequency :50 / 60Hz, Waveform: Simulated Sine wave
- Transfer Time:Â 2-6ms typical
- Noise level:Â less than 40 dB
- Dimensions:Â 313mm (D) by 129mm (W) x 175mm (H)
Mercury 1050va ups
Mercury 850 va ups
- Excellent microprocessor control for Super Performance
- Intelligent battery management for Longer Battery Life
- Comprehensive and reliable protection to Safeguard Your Equipment
- Boost and buck AVR for voltage stabilization
- Built-in super-fast charger that shortens charging time
- Off mode charging function
- Optional no-load shutdown
- Built-in self-diagnostic function
- Auto restart while AC is recovering
- Power-on self-test
- Sinewave Power Output
- Humanized Alarm System
- Line Interactive UPS